ALTANET CRAIOVA // IT SERVICES & SECURITY SYSTEMS SINCE 2003
[email protected] Mon–Fri 09:00–18:00 · Sat 10:00–14:00 HOTLINE: 0351 444 444
Contact
// OUG 155/2024 · LAW 124/2025 · DIRECTIVE (EU) 2022/2555

NIS2 compliance, from registration with the Romanian National Cyber Security Directorate (DNSC) to your first audit.

We help you find out whether your company or public body falls under NIS2, register correctly with DNSC and implement the technical and organisational measures the law requires. Not just paperwork: secured networks, tested backups and real monitoring.

WHAT THE LAW REQUIRES, IN BRIEF

  1. Registration with DNSC

    within 30 days of meeting the criteria

  2. Risk management measures

    technical, operational and organisational (Art. 21)

  3. Incident reporting

    early warning within 24h, notification within 72h, final report within 1 month

  4. Management accountability

    senior management approves the measures and is accountable for them

// WHAT IS NIS2

The law that makes cybersecurity a duty of management, not just of IT.

The NIS2 Directive was transposed in Romania by Government Emergency Ordinance (OUG) 155/2024, approved by Law 124/2025. It greatly extends the list of organisations required to protect their networks and information systems: from hospitals, town halls and utilities to manufacturers, transport operators, courier companies and IT service providers. The competent authority is DNSC.

Official text of the NIS2 Directive (European Commission) (opens in a new tab)

More sectors

18 sectors, split into “sectors of high criticality” (Annex I) and “other critical sectors” (Annex II).

Concrete measures

Risk analysis, backup and business continuity, access control and MFA, vulnerability management, supply chain security, training.

Short deadlines

Significant incidents must be reported to DNSC within hours, not weeks. Without a plan in place, the deadlines cannot be met.

Management is accountable

Management bodies approve the measures, oversee their implementation and must attend security training.

// DOES NIS2 APPLY TO YOU?

Find out in 30 seconds whether NIS2 applies to your organisation.

The general rule: NIS2 covers entities in the sectors listed in the annexes that are at least medium-sized enterprises, meaning 50 or more employees, or an annual turnover and balance sheet above EUR 10 million.

There are exceptions to the size criterion: some digital and communications service providers, public administration entities, and entities designated directly by DNSC. The result shown here is indicative; the final classification depends on your actual activity.

Annex I

Energy, transport, banking, financial market infrastructures, health, drinking water, waste water, digital infrastructure, managed ICT services (B2B), public administration, space.

Annex II

Postal and courier services, waste management, chemicals, food, manufacturing (medical devices, electronics, electrical equipment, machinery, motor vehicles), digital providers, research.

1. Which sector do you operate in?
2. How large is your organisation?

Choose your sector and size to see the result.

// WHY REGISTER WITH DNSC

Registration is not a formality. It is the first thing DNSC checks.

It is a legal obligation

Entities that meet the criteria must register with DNSC within 30 days. Failing to register is itself a sanctionable offence.

It triggers the other obligations

Registration is followed by a self-assessment of your maturity level, a plan of measures and the appointment of the person responsible for network and information system security.

It puts you on the support map

Registered entities receive alerts and can report incidents through the official channel, with support from DNSC’s response teams.

It counts during an inspection

A registered organisation with documented measures being implemented shows due diligence. One that has not registered starts from the weakest position.

// WHAT YOU RISK IF YOU DO NOT COMPLY

Fines are only part of the cost.

ESSENTIAL ENTITIES

up to EUR 10m

or 2% of total worldwide annual turnover, whichever is higher

IMPORTANT ENTITIES

up to EUR 7m

or 1.4% of total worldwide annual turnover, whichever is higher

GDPR, IF PERSONAL DATA IS AFFECTED

up to EUR 20m

or 4% of turnover, imposed separately by ANSPDCP (the Romanian data protection authority)

  • Measures ordered by DNSC — warnings, binding instructions with deadlines, security audits imposed at the entity’s expense.

  • Liability of management — for essential entities, the law even provides for a temporary ban on holding management positions.

  • Contracts and tenders — clients and contracting authorities increasingly ask suppliers for proof of security measures.

// SCENARIO: RANSOMWARE OR DATA LOSS

Monday morning, the servers are encrypted. What happens next?

A ransomware attack does not just stop your operations. Under NIS2 it also starts a reporting clock. If personal data is affected, a second clock starts, towards ANSPDCP.

  1. T+0

    Detection

    Isolate the affected systems, preserve evidence, activate the response plan.

  2. ≤ 24h

    Early warning to DNSC

    Including whether the incident appears to be caused by unlawful action or has a cross-border impact.

  3. ≤ 72h

    Notification to DNSC and ANSPDCP

    Initial assessment of severity and impact, indicators of compromise. ANSPDCP, if personal data is involved.

  4. ≤ 1 month

    Final report

    Root cause, measures applied and impact. An intermediate report, if DNSC requests one.

Unprepared

  • The backup was on the same network and was encrypted along with the servers.
  • The backups had never been tested by restoring them.
  • Nobody knows who notifies DNSC, what information is sent or by when.
  • Operations stop for days or weeks, and paying the ransom does not guarantee the data comes back.

With NIS2 measures in place

  • Isolated backup, with offline or immutable copies and regularly tested restores.
  • Segmented network, MFA and controlled privileged accounts that limit the spread.
  • Monitoring and alerting, so the attack is stopped in its early stages.
  • An incident response procedure and notification templates prepared in advance.
// WHAT WE DO FOR YOU

Consultancy and implementation, from the same team.

We work with town halls, healthcare providers and companies. Beyond the documentation, we actually configure the firewalls, backups and monitoring.

Classification and DNSC registration

We establish whether you are an essential or important entity and prepare your registration file.

Risk analysis and gap analysis

Asset inventory, risk assessment and comparison with the Art. 21 requirements, with a prioritised plan of measures.

Policies and procedures

Security policy, incident management, BCP/DRP, backup, access control, suppliers, training.

Technical implementation

FortiGate and MikroTik hardening, segmentation, VPN, MFA, isolated backup, vulnerability and patch management.

Monitoring and incident response

SOC monitoring with Wazuh, triage and investigation, support with notifications to DNSC and ANSPDCP.

Staff and management training

Cyber hygiene for employees and the mandatory training for management bodies.

// HOW WE WORK TOGETHER

  1. STEP 1

    Initial call

    We get to know your activity and infrastructure.

  2. STEP 2

    Assessment

    Classification, risk analysis and gap analysis.

  3. STEP 3

    Implementation

    Technical measures and documentation.

  4. STEP 4

    Maintenance

    Monitoring, restore tests, annual review.

// FREQUENTLY ASKED QUESTIONS

What our clients ask us most often

// REQUEST A QUOTE

Find out where you stand on NIS2.

Leave us a few details and we will get back to you to discuss your classification and the next steps.

This site is protected by reCAPTCHA; the Google Privacy Policy and Terms of Service apply.